3.5" Form Factor

PC/104

PC/104-Plus

PCIe/104

PCI/104-Express

COM Express

Single Board Computers

I/O Modules

Power Supplies

Single Board Computers

I/O Modules

Power Supplies

I/O Modules

Single Board Computers

Cables

PC/104

Adapters

PC/104

PC/104-Plus

PCIe MiniCard

PC/104

PCIe MiniCard

PC/104

PC/104-Plus

PCI/104-Express

PCIe MiniCard

PC/104-Plus

PCIe MiniCard

PC/104-Plus

PCIe MiniCard

I/O Modules

Single Board Computers

I/O Modules

PC/104

PC/104-Plus

PC/104

Small form factor

Ethernet Switch Modules

Single Board Computers

Ethernet Switches

AGX Orin Solutions

ORIN Nano / NX

Nano and NX Solutions

AGX Xavier Module Solutions

TX2 / TX2i Module Solutions

You may also like:
DS-MPE-CAN2L Dual CANbus 2.0 PCIe MiniCard Module

Products   >   Communications Modules   >   CAN I/O   >   Janus-MM-LP
      JANUS-MM-LP  PC/104 & PC/104-Plus dual/quad CAN modules with isolation   pc104plus    PC104
OverviewBlock DiagramSpecificationsOrdering
Information
Support

Description

The Janus-MM-4LP-XT family of I/O modules offers two or four opto-isolated CANbus 2.0B ports plus 16 digital I/O lines. Models are available in both the PC/104-Plus and PC/104 form factors. An FGPA core houses the CAN controller logic and digital I/O logic providing data rates up to 1Mbps. Each CAN port supports standard and extended frames as well as expanded TX and RX message queues for enhanced performance. Each port has its own combination isolator and transceiver chip.

Janus-MM-4LP-XT fits a wide variety of rugged and on-vehicle embedded serial I/O application needs. It was designed with harsh applications in mind including latching connectors to further improve reliability. Extended temperature operation of -40°C to +85°C is tested and guaranteed. The module is compatible with MIL-STD-202G shock and vibration specifications.

Software

Janus-MM-LP: Communications Modules, , PC/104-<i>Plus</i>

I/O Cables

Diamond Systems offers cables for use with the Janus-MM-4LP-XT family of PC/104-Plus CANbus modules. Please refer to the table below for the available cables.

Cable Description
6981164 20-pin, 12 inch digital I/O cable, 1 per board
6981182 CANbus 2.0 cable, 1 per CAN port

Janus-MM-LP: Communications Modules, , PC/104-<i>Plus</i>

CAN Circuit
Number of CAN ports 2 or 4 CANbus 2.0B
Data rates Up to 1Mbps
Controller FPGA based
Transceiver ADM3053 isolation + transceiver
Isolation 500V port-to-port and port-to-host
Frames Standard 11-bit identifier
Extended 29-bit identifier
Message queues Expanded TX and RX message queues
16 8-byte transmit message queues
31 8-byte receive message queues
Receive filters 16
Termination Jumper selectable biased split termination
Digital I/O
Number of lines 16 programmable DIO lines arranged in 2 8-bit ports
Logic levels 3.3V or 5V, jumper selectable
Pull-up/pull-down Jumper selectable
Direction control Software programmable
General
Host interface PCI or ISA, self selecting
Connectors Latching connectors for increased ruggedness
Input power +5VDC 5%
Power consumption tbd W at 5VDC
Operating System support Windows Embedded Standard 7
Linux Ubuntu 12.04LTS
Operating temperature -40°C to +85°C (-40°F to +185°F)
Operating humidity 5% to 95% non-condensing
Shock MIL-STD-202G compatible
Vibraion MIL-STD-202G compatible
MTBF tbd hours at 20°C
Form Factor PC/104-Plus:
3.55" x 3.775" (90mm x 96mm)
Weight 2.5oz (71g)
RoHS Compliant

Get an online quote

 
Janus-MM-LP
Available Models:
CK-JNMM2LP
Cable Kit, Janus-MM-2LP Dual Port CAN PC/104 Module
Stocked
Buy Now
CK-JNMM4LP
Cable Kit,Janus-MM-4LP
Stocked
Buy Now
JNMM-4LP-XT
Quad isolated CAN port PC/104-Plus Module with 16 Digital I/O
Available
JNMM-4L-XT
Quad isolated CAN port PC/104 Module with 16 Digital I/O
Available
Buy Now
JNMM-2LP-XT
Dual isolated CAN port PC/104-Plus Module with 16 Digital I/O
Available
Buy Now
JNMM-2L-XT
Dual isolated CAN port PC/104 Module with 16 Digital I/O
Available
Buy Now
Please login or signup for an online quote request.

Product Support for Janus-MM-LP

User Manual

Janus-MM-4LP Hardware User Manual(.pdf, 812.0 KB)
Janus-MM-4LP Linux Software User Manual(.pdf, 1.6 MB)
Drivers

JNMM-4LP-XT Linux 32-bit Driver(.zip, 9.8 MB)
JNMM-4LP-XT Windows Driver(.zip, 23.0 MB)
JNMM-LP Win10 64-bit Driver(.zip, 7.4 MB)
JNMM-LP board driver for windows 10 64-bit driver
Datasheet

Janus-MM-4LP Datasheet(.pdf, 358.0 KB)
FEATURES
2 or 4 CAN 2.0B ports
Data rates up to 1Mbps
Supports standard (11-bit identifier) and extended (29-bit identifier) frames
Expanded TX and RX message queues for enhance performance
16 8-byte transmit message queues
31 8-byte receive message queues
16 receive filters
Galvanically isolated transceivers
500V port-to-host and port-to-port isolation
Jumper selectable biased split termination for improved noise reduction
16 digital I/O lines
Latching connectors for increased ruggedness
PCI and ISA bus interfaces
Basic CAN driver included with APIs and monitor program
Supports Linux Ubuntu 12.04LTS and Windows Embedded 7
PC/104-Plus form factor:
3.55" x 3.775" (90mm x 96mm)
Extremely rugged -40°C to +85°C operation
MIL-STD-202G shock and vibration compatible
ONLINE SUPPORT
See Janus-MM-LP Technical Resources
Request Product information
Request Technical Support
DOWNLOADS
Janus-MM-4LP Linux Software User Manual
(.pdf, 1.6 MB)
Janus-MM-4LP Hardware User Manual
(.pdf, 812.0 kb)
Janus-MM-4LP Datasheet
(.pdf, 358.0 kb)